It is a device that performs the function of regulating the battery’s charge , protects the battery against overloading and over-discharge to enhance the life of the battery, and helps the solar system to use effectively. fruit and lasting. – The controller also shows the charge status of the solar panel on the battery to help users control the loads. – The controller also performs protection against overvoltage (> 13.8V) or low voltage (<10.5V). The controller protection circuit will perform a circuit break when the controller confirms that the battery is fully charged or the battery voltage is too low.
Instruction manual & connection diagram:
– Use within the range of machine specifications.
– Carefully observe the input and output terminals before connecting the pole (+) to the pole (+), the pole (-) against the pole (-).
– Led lights show:
+ Led charging indicator:
Lights off: No charging, no connection to solar panels or weak sunlight
Light on: The indicator is charging
Flashing light: Full battery indicator or charging indicator
+ Led battery capacity indicator :
Green indicator light: Full alert
Yellow indicator LED: Normal report
Red indicator light blinks: Low voltage protection for the battery
+ Led download notification:
Open leds: Download
Led off: Download
Led light blinks: Off load, output overload or short circuit
Specifications
Model |
PWM20B |
|||
Solar battery voltage input automatically | 12vDC | 24vDC | ||
Charging line | 30A Max. | |||
Output voltage automatic battery load | 12vDC | 24vDC | ||
Maximum voltage of solar batteries | 19vDC | 28vDC | ||
Maximum charging current for solar batteries | 30A Max. | |||
Loss line | 6mA | |||
Charging disconnection threshold (battery full) | 14.4V ± 2% | 28.8V ± 2% | ||
Recharging threshold | 13.6V ± 2% | 27.2V ± 2% | ||
Auto overload overload protection | I> 30A | |||
Low voltage protection Auto battery disconnect | U ≤ 11.1V ± 2%. | U ≤ 22.2V ± 2%. | ||
Automatically reconnect | 12.6V | 25.2V | ||
Dimensions (mm) hxwxd | 168 x 88 x 34 | |||
Storage temperatures | -35 ° C – 70 ° C | |||
Working temperature | -25 ° C – 60 ° C |
Lưu Ý : Thông Số Kỹ Thuật Trong Mô Tả Chỉ Mang Tính Chất Tham Khảo Và Có Thể Thay Đổi Mà Không Cần Phải Thông Báo Trước .
Picture
Application
– Control charging and regulating the battery charge in the solar power system, supplying electricity to household electric equipment such as lighting, televisions, CD players, Video systems, computer stands, telephone exchange, computers fax, fan, water pump, internet or company, office building …
Application model for non-chargers for batteries from the national 220v power grid, only use from 12v to 220vac batteries: